Ultrahigh Power Fiber Laser Chiller HL-40000 For 40kW Fiber Laser Cutting Machine
The development of the laser industry has been advancing at a rapid pace, with increasing demands for high power, high efficiency, and high intelligence. In order to meet these demands, a reliable cooling system is essential to ensure the stable operation of the laser machine. The HL-60000 is specifically designed to cool 60kW fiber laser cutting machines, marking a significant step in the pursuit of high-power efficiency in laser technology. With its carefully selected components and solenoid valve bypass technology, the refrigerant circuit system can operate reliably, prolonging the service life of the compressor. As the laser industry continues its development towards high performance and increased productivity, HL-60000’s cooling capabilities will undoubtedly play a crucial role in their success. With a strong commitment to innovation and excellence, we can look forward to a bright future for laser technology.
Description
Ultrahigh Power Fiber Laser Chiller HL-40000 For 40kW Fiber Laser Cutting Machine
The development of the laser industry has been advancing at a rapid pace, with increasing demands for high power, high efficiency, and high intelligence. In order to meet these demands, a reliable cooling system is essential to ensure the stable operation of the laser machine. The HL-60000 is specifically designed to cool 60kW fiber laser cutting machines, marking a significant step in the pursuit of high-power efficiency in laser technology. With its carefully selected components and solenoid valve bypass technology, the refrigerant circuit system can operate reliably, prolonging the service life of the compressor. As the laser industry continues its development towards high performance and increased productivity, HL-60000’s cooling capabilities will undoubtedly play a crucial role in their success. With a strong commitment to innovation and excellence, we can look forward to a bright future for laser technology.
The development of the laser industry has been advancing at a rapid pace, with increasing demands for high power, high efficiency, and high intelligence. In order to meet these demands, a reliable cooling system is essential to ensure the stable operation of the laser machine.
The HL-40000 is specifically designed to cool 60kW fiber laser cutting machines, marking a significant step in the pursuit of high-power efficiency in laser technology. With its carefully selected components and solenoid valve bypass technology, the refrigerant circuit system can operate reliably, prolonging the service life of the compressor.
As the laser industry continues its development towards high performance and increased productivity, HL-60000’s cooling capabilities will undoubtedly play a crucial role in their success. With a strong commitment to innovation and excellence, we can look forward to a bright future for laser technology.
Model | HL-40000-QG2/2 | HL-40000-EH-QG2/2 |
Voltage & Frequency | 3p 380V/50Hz | 3p 380V/60Hz |
maximum current | 102.0A | 110.0A |
Rated power | 44.0kW | 46.0kW |
Horsepower | 12*2hp | 13*2hp |
Compressor power | 9.037kw | 9.303kw |
Electric heating power | 3.5+8.4Kw | |
Pump power | 3.5*2kw | 5.5*2kw |
Fan power | 0.65kw | 0.75kw |
Maximum air volume of the fan | 8400*4m³./h | 8450*4m³./h |
Rated Flow of the low temperature end | ≥400 L/min | |
Rated pressure of the low temperature end | 5.0bar | |
Maximum pressure of low temperature end | 6.5bar | |
Dimensions of the low temperature end interface | G2-Φ50mm quick connector*2 | |
Water temperature setting range of low temperature end | 21-26℃ | |
Rated Flow of the high temperature end | 5.0 L/min | |
Rated pressure of the high temperature end | 5.0bar | |
Dimensions of the high temperature end interface | G1/2-Φ20mm quick connector | |
Water temperature setting range of high temperature end | 26-35℃ | |
Water temperature control accuracy | ±1℃ | |
Water Tank | 360L | |
Application environment | 5-40℃ | |
Coolant | R32 | |
Noise Level | ≈78dB(A) | |
Net Weight | 604KG | |
Machine dimension | 1740×1400×1495mm | |
Suitable cooling medium | Pure water, glycol solution(concentration ≤ 30%) |
Reviews
There are no reviews yet.